DrägerSensor MEC NH3 – 68 12 750
Elektrochemischer DiffusionsSensor für DrägerTransmitter. Zur Überwachung der Ammoniak (NH 3) Konzentration in der Umgebungsluft. Inbetriebnahme eines neuen Sensors Der Sensor ist werkseitig mit NH3 und Nullgas kalibriert. Kalibrierdaten und Grundeinstellungen sind im internen Datenspeicher des Sensors abgelegt. In geeigneten DrägerTransmittern (siehe Gebrauchsanweisung des Transmitters ...
Why is hydrogen such a big issue for CO sensors? | GfG ...
CO sensors also respond strongly to acetylene gas. Since the internal filter does not absorb acetylene, the sensor shows a very strong and immediate response to this gas. GfG Technical Note 2019, “G460 and Micro IV electrochemical (EC) toxic sensor relative response matrix” includes a chart listing some of the most common documented interferences for the electrochemical sensors used in GfG ...
6809605 | Drager | Carbon Monoxide (CO) Electrochemical Sensor
Drager Polytron Carbon Monoxide (CO) Electrochemical Sensor ; 5 to 1000 ppm Detection Range . Is Drager 6809605 not the part you are wanting? Check out the rest of our store to see what else we have to offer! 4D Controls is proudly owned and operated by a team of Automation and Electrical Engineers. Since 2005, we have been supplying the ...
Carbon monoxide CO Draeger
Dräger Pac ® 8500. Singlegas detector. for personal air monitoring. Detection of two gases at once with a dual sensor for O 2 / CO or H 2 S / CO. Use with a hydrogencompensated CO …
Instructions for useDrägerSensor68 09 605 CO 68 ... …
Elektrochemischer DiffusionsSensor für DrägerTransmitter. Zur Überwachung der Kohlenmonoxid (CO)Konzentration in der Umgebungsluft unter Umgebungsbedingungen. 2 Inbetriebnahme Der Sensor ist werksseitig mit CO und Nullgas kalibriert. Kalibrierdaten und Grundeinstellungen sind im internen Datenspeicher des Sensors abgelegt. In geeigneten DrägerTransmittern (siehe …
Dräger XXS Electrochemical Sensor Carbon Monoxide CO ...
Elektrochemischer DiffusionsSensor für DrägerTransmitter. Zur Überwachung der Schwefeldioxid (SO2) Konzentration in der Umgebungsluft unter Umgebungsbedingungen. 2 Inbetriebnahme Der Sensor ist bei werksseitig mit SO2 und Nullgas kalibriert. Kalibrierdaten und Grundeinstellungen sind im internen Datenspeicher des Sensors abgelegt. In ...
DrägerSensor XS NF3 – 68 11 125
Elektrochemischer DiffusionsSensor für den Pyrolyzer Polytron 3500/7500. Zur Überwa chung der Stickstofftrifluorid (NF3)Konzentration in der Umgebungsluft. 2 Inbetriebnahme eines neuen Sensors Kalibrierdaten und Grundeinstellungen sind im internen Datenspeicher des Sensors abgelegt. 3 Nullpunkt kalibrieren Den Pyrolyzer über ein TStück oder einen Gasbeutel mit Nullgas (Stickstoff oder ...
DrägerSensor NO2 LC – 68 13 205
Elektrochemischer DiffusionsSensor für DrägerTransmitter zur Überwachung der Stickstoffdioxid ... Available on the Internet at or on request from your Dräger dealer. _____ ® DrägerSensor and SensorReady are registered trade marks of Dräger in Germany. * All data represents typical values, applies to new sensors and ambient conditions of 20 °C, 50 % and 1013 mbar ...
Dräger XXS Electrochemical Sensor Carbon Monoxide CO ...
Dräger XXS Electrochemical Sensor Carbon Monoxide CO Extended Warranty Measuring Carbon Monoxide CO Extended Warranty Range 0–2000ppm Calibration Interval 0 Warranty 5 year warranty Suitable For: PAC 7000, Xam 2000, XAm 2500, XAm 5000, XAm 5600 Click To Download Sensor Data Sheet Dräger XXS Electrochemical Sensor Dräger has developed miniature electrochemical …
Welcome to Draeger Canada Leading Medical Safety ...
Draeger Canada. 2425 Skymark Ave, Unit 1. Mississauga, ON L4W 4Y6. +1 8773724371. Call us from 8 am 5 pm (ET), Monday Friday.
Draeger 6811410 Electrochemical Sensor, 1 Ppm CO, 1 Ppm ...
Draeger Safety: MFR Part Number: 6811410: UNSPSC: 46171613: Item: Electrochemical Sensor: Suitable For Use With: Xam 5600 Series MultiGas Monitors: Detects: Carbon Monoxide/Hydrogen Sulfide: Sensor Range: 0 – 2000 ppm CO, 0 – 200 ppm H2S: Resolution: 1 ppm CO, 1 ppm H2S: Temperature Range 4 to 122 deg F
Draeger Safety PAC 8500 Gas Monitor with Carbon Monoxide ...
The Dräger Pac 8500 is part of Draeger''s next generation of portable gas measuring and warning instruments. The Pac 8500 features dual sensors, a full datalogger, exposure alarms (STEL/TWA) and a powerful battery. This model is: Dräger Pac 8500 Carbon Monoxide Hydrogen Compensated (CO H₂CP) Measuring Range: 0 2000 ppm Resolution: 2 ppm
Dräger Polytron 7000 Gas Detector | Dräger
The builtin sensor data memory containing all the relevant gas and calibration information, together with on board temperature and pressure compensation gives the DrägerSensor its unsurpassed measurement performance. This also allows the Polytron 7000 to accept precalibrated sensors, with minimal operator intervention, the Dräger Polytron 7000 is a virtually maintenance free transmitter ...
DrägerSensor MEC CO – 68 12 730
Elektrochemischer DiffusionsSensor für DrägerTransmitter. Zur Überwachung der Kohlenmonoxid (CO)Konzentration in der Umgebungsluft. Inbetriebnahme eines neuen Sensors Der Sensor ist werkseitig mit Kohlenmonoxid (CO) und Nullgas kalibriert. Kalibrierdaten und Grundeinstellungen sind im internen Datenspeicher des Sensors abgelegt. In geeigneten DrägerTransmittern (siehe ...
Dräger Gas Detection Catalog Safety on board | Dräger
DrägerSensors ®, XXS and PID ... Xam 1700 EX, O 2, CO, H 2S w/ alkaline battery pack 83 18 730 Accessories NiMH battery pack T4 83 18 704 NiMH battery pack T4 with charger module and power pack 83 18 785 Alkaline battery pack T3/T4 (without alkaline batteries) 83 18 703 Alkaline battery for alkaline power supply 8318703 (2 required) 45 43 708 Dräger Bump Test Station for Xam 1700/2000 83 ...
Safety Supply America XS Sensors
Dräger XS Installed Sensor CO CL2 Phosgene Drager 4595442. Price: Dräger XS Installed Sensor CO Drager 4595433. Price: Dräger XS Installed Sensor CO2 Drager 4595414. Price: Dräger XS Installed Sensor COHC Drager 4595431 ...